Article
Automated Aseptic Bioreactor Sampling: How It Works and How to Choose
By QB Systems · 10 min read
A practical guide for process-development and bioprocess R&D teams that are moving from manual to automated sampling.
What automated bioreactor sampling is
Automated bioreactor sampling means that a machine, not a person, takes samples from a bioreactor or fermenter. It draws a defined volume at a defined time, moves it through a fluid path, and puts it where it is needed: a cooled vial for later analysis, or an analyser for an immediate result. The sampling time, the volume and what happened to the sample are recorded by the control software.
Every automated sampler, whatever its brand, has the same building blocks:
- A connection to the vessel, usually a sampling port or probe, sometimes with a cell-retention filter.
- A fluid path of tubing, valves and a pump that moves the sample.
- A cleaning step that flushes, rinses or dries the path between samples, so one sample does not carry over into the next.
- A destination: vials in a rack (often cooled), an analyser, a fraction collector or waste.
- Software that decides when to sample, from which vessel, how much, and what to do with it, and that keeps the record.
The differences between systems are in how far each block goes: how many vessels one system serves, how samples are prepared, which analysers are connected directly, and how open the software is to the rest of the lab.
Manual vs. automated sampling
Manual sampling is the default in most labs, and it works. It also sets limits that become visible as soon as a team runs several bioreactors in parallel or long cultivations.
| Manual sampling | Automated sampling | |
|---|---|---|
| Who and when | A trained person at the port, during working hours | Scheduled or triggered by the process, 24/7 |
| Volume and timing | Varies between people and shifts | The same volume at the set time, every time |
| Contamination path | Every manual connection opens one | Fewer manual interventions on the vessel |
| Parallel vessels | One port at a time; staff time grows with each vessel | Several vessels from one system |
| Sample stability | Samples can wait at room temperature before analysis | Cooled storage or direct transfer to an analyser |
| Records | Paper or manual entry | Time, volume, source and destination logged by software |
| Upfront effort | Low | A system to buy, install and qualify |
Automation pays off when the cost of manual work, missed night-time samples and repeated runs exceeds the cost of the system. That is typically the case for labs running parallel cultivations, fed-batch and perfusion processes with frequent sampling, or processes where night and weekend samples carry the most information.
What “aseptic” means in practice
Vendors use several terms for protection against contamination, and they are not interchangeable. A useful definition treats aseptic sampling as a whole workflow:
- Fluid path, connectors and containers that are decontaminated or single-use.
- A defined procedure for assembling, connecting and operating them.
- Documentation that shows what was done for each sample.
Hardware alone is not enough: an aseptic capability needs consumables and a written procedure as well. When you evaluate a system, ask which of the three the vendor provides as a product and which you would have to define and validate yourself. Where a vendor’s public material is silent, put the question to the vendor in writing.
How an automated sampler works, step by step
Most systems follow the same four steps, with different degrees of automation in each.
- Draw. The pump pulls a set volume from the vessel through the selected port. Some systems discard a first volume to clear the line, so the sample reflects the culture now, not the liquid left in the tube.
- Clean. The path is washed, rinsed and often air-dried, before and after each sample. The cleaning medium, the number of cycles and the volumes decide how much carry-over remains.
- Prepare. Depending on the system, the sample is diluted, split into aliquots or filtered before it reaches its destination.
- Store or deliver. The sample goes to a vial, often held at 4 °C, or directly to an analyser. Cooling matters: a sample that sits warm loses analytical value.
Connecting samplers to analysers
There are two ways to get from sample to result:
- Off-line, through cooled vials. Samples are collected and kept cold, then analysed in batches. This is flexible, works with any analyser and suits labs that analyse once or twice a day.
- At-line, by direct transfer. The sampler sends the sample straight into an analyser, such as a metabolite analyser, a cell counter or an HPLC. Results come back within minutes and can, in some systems, drive the next control action.
Systems differ widely here. In public vendor material, for example, Securecell Numera documents transfer to up to six analysers with a named list of supported devices, the Flownamics Seg-Flow S3 delivers to up to four analysers or fraction collectors, and the Eppendorf Bioprocess Autosampler transfers to a Nova BioProfile FLEX2 or to tempered vials. The sources and details are in our comparative analysis of benchtop automated sampling.
If your analysers are already chosen, ask every vendor for a written list of verified analyser interfaces before you decide.
The main types of systems
Automated samplers on the market follow a few different designs:
- Built for one bioreactor family. The sampler is part of a vendor’s bioreactor ecosystem and runs inside the same control software, for example the Eppendorf Bioprocess Autosampler with DASbox and DASGIP systems.
- Preparation and routing stations. A stack of modules prepares samples and routes them to several analysers, for example Securecell Numera.
- Segmented-flow samplers. Samples travel as segments through a cleaned line to analysers or collectors, for example the Flownamics Seg-Flow.
- Aseptic sampling devices with a controller. Sampling devices at each vessel are routed by a controller to analytical destinations, for example Merck MAST.
- Modular, software-defined samplers. The sampler is assembled from standard pump, valve and controller modules and configured in software, which is the approach of the QB AutoSampler.
Each design has applications where it is the right choice. The comparison pages linked above set out, vendor by vendor, what each one publishes and where QB is weaker or simply different.
How to choose: six questions
- What is your bioreactor ecosystem? If all your vessels come from one vendor and you want sampling inside that vendor’s software, its own sampler is the natural fit. With mixed equipment, ask every vendor for verified bioreactor interfaces.
- Where must samples go? Direct transfer to named analysers, or cooled vials for later analysis? Compare documented analyser integrations, storage temperature and vial capacity.
- How much preparation must the sampler do? Wide dilution ranges or filtration in the instrument, or a simple dilution and aliquoting step?
- Do results have to drive the process? If analyser results must trigger feeding or control actions, check that this is a documented function, not a project.
- What assurance and records do you need? Ask about aseptic documentation, audit trails, reports and electronic signatures, and whether each is shipped or planned.
- How will the system grow? Ask what each next vessel requires: more hardware, another licence, vendor service, or a pause in running processes.
The market for automated aseptic sampling
Automated sampling is a growing equipment category. Grand View Research estimates the automatic aseptic sampling market at USD 517 million in 2025, growing to about USD 1.08 billion by 2033, a compound annual growth rate of 9.7%. Upstream applications, which include bioreactor sampling, are the largest share, at 59.5%. The estimate covers more than benchtop autosamplers: consumables and downstream sampling are included.
Source: Grand View Research, Automatic Aseptic Sampling Market Size Report, 2026–2033.
Where the QB AutoSampler fits
The QB AutoSampler is a modular sampler for bioprocess R&D. It is built from QB Modules (a selector valve, a syringe pump and QB Edge), runs in QB Control, and takes samples from your vessel to a cooled vial with configurable path cleaning, in-vial dilution and split aliquoting. For aseptic work, it uses dedicated consumable sets with an A4BEE-provided procedure for assembly and operation, and an aseptic testing report is available on request. It grows by adding modules, and it is sold with a perpetual licence.
It is not the right tool for every lab. QB documents no named analyser integrations, its dilution covers factors up to 6, and it is positioned for non-regulated R&D and process development. If your work needs direct transfer to several named analysers or wide dilution ranges, compare the vendor pages linked above.
Frequently asked questions
Is automated sampling worth it for a lab with only a few bioreactors?
It depends on how often you sample and when. Even with two to four vessels, night and weekend samples, long perfusion runs and tight sampling schedules can justify automation. With a modular system, a lab can start with one vessel and add sources later.
Can one autosampler serve bioreactors from different vendors?
Some systems are tied to one vendor’s bioreactors and software; others connect to any vessel with a suitable sampling port. Ask for a written list of verified interfaces, and test the connection on your own vessel before you buy.
Does automated sampling remove the contamination risk?
No system removes it entirely. Automation reduces the number of manual interventions at the vessel; the remaining risk depends on the fluid path, the consumables, the cleaning procedure and how they are documented.
What sample volume does an autosampler take?
It varies by system and setting, from about a millilitre to tens of millilitres per sample. For small vessels, check how much volume each sample removes in total, including any discarded first volume and the volume left in the line.
Related: QB AutoSampler · Benchtop automated sampling: comparative analysis · All comparisons